Technical Information:
Planar lightwave circuit (PLC) splitter is a type of optical power management device that is fabricated using silica optical waveguide technology to distribute optical signals from Central Office (CO) to multiple premise locations. Blockless PLC splitter has stronger fiber protection than bare fiber splitter, which is a miniaturization result of cassette splitter. It's mainly used for various connection and distribution boxes or network cabinets.
Application:
► EPON/GPON;
► FTTX;
► Passive Optical Networks;
► CATV, LAN, WAN;
► Test Instrument.
Features:
► Wavelength Insensive;
► Low Loss;
► Low Polarize on Dependence;
► Environmentally Stable;
► Excellent Uniformity;
► GR-1209-CORE.
Technical Data:
Parameter | Port Configuration |
||||||
1x2 |
1x4 |
1x8 |
1x16 |
1x32 |
1x64 |
||
Fiber Type |
SMF-28e |
||||||
Operating Wavelength (nm) |
1260~1650 |
||||||
Insertion Loss(dB) |
Typical |
3.9 |
7.0 |
10.2 |
13.2 |
16.2 |
19.7 |
Max |
4.2 |
7.4 |
10.7 |
13.7 |
17.1 |
21.2 |
|
Loss Uniformity (dB) |
Max |
0.4 |
0.6 |
0.8 |
1.2 |
1.5 |
2.5 |
Return Loss (dB) |
Min |
50 |
50 |
50 |
50 |
50 |
50 |
PDL(dB) |
Max |
0.2 |
0.2 |
0.3 |
0.3 |
0.3 |
0.4 |
Directivity(dB) |
Min |
55 |
55 |
55 |
55 |
55 |
55 |
Wavelength Dependent Loss(dB) |
Max |
0.3 |
0.3 |
0.3 |
0.5 |
0.5 |
0.8 |
Temperature Dependent Loss |
Max |
0.5 |
0.5 |
0.5 |
0.8 |
0.8 |
1.0 |
Operating Temperature (℃) |
-40~+85 |
||||||
Storage Temperature (℃) |
-40~+85 |
||||||
Note: |
Ordering Information:
PLC Splitter
FPS | Port Configuration |
Input Fiber Type |
Input Fiber Length |
Output Fiber Type |
Output Fiber Length |
Input Connector |
Output Connector |
A=ALTEK |
102=1x2 |
B=250um Bare Fiber |
10=1.0m |
B=250um |
10=1.0m |
0=None |
0=None |
P=PLC |
104=1x4 |
L=900um Loose Tube |
15=5.0m |
R=Ribbon Fiber |
15=5.0m |
1=FC/UPC |
1=FC/UPC |
S=Splitter |
108=1x8 |
T=900um Tight Buffer |
20=2.0mm |
F=Fanout Box With 900um Loose Tube |
20=2.0mm |
2=LC/APC |
2=LC/APC |
116=1x16 |
3=SC/APC |
3=SC/APC |
|||||
........ |
4=SC/PC |
4=SC/PC |
|||||
202=2x2 |
........ |
........ |
|||||
216=2x16 | |||||||
264=2x64 | |||||||
........ |
PLC Splitter Module
FPM | Port Configuration |
Modules Type |
Cable Type |
Fiber Length |
Input Connector |
Output |
F=ALTEK |
102=1x2 |
B=250um |
09=0.9mm |
10=1.0m |
0=None |
0=None |
P=PLC |
104=1x4 |
L=900um Loose Tube |
20=2.0mm |
15=5.0m |
1=FC/UPC |
1=FC/UPC |
M=Module |
108=1x8 |
T=900um |
30=3.0mm |
20=2.0mm |
2=LC/APC |
2=LC/APC |
116=1x16 |
........ |
3=SC/APC |
||||
........ |
4=SC/PC |
|||||
202=2x2 |
........ |
|||||
216=2x16 | ||||||