110kV 3-Phase 2-Winding Power Transformer

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Beijing
Validity to: Long-term effective
Last update: 2022-07-11 17:58
Browse the number: 255
inquiry
Company Profile
 
 
Product details

Part Ⅰ: 110kV Power Transformer Overview

110KV power transformers is designed and optimized by absorbing and utilizing advanced technologies at home and abroad to optimize the transformer core, coil, body, leads, fuel tank and other components, which features low partial discharge, low loss, low noise, light weight and high reliability. 110kv power transformer type: Three Phase Two Wingding OLTC/NLTC Power Transformer and Three Phase Three Wingding OLTC/NLTC Power Transformer.


110kV 3-phase 2-winding Power Transformer

Product Attributes

Model No.


Application

Power

Coil

Core-type Transformer

Frequency

50/60Hz

Phase

Three

Cooling Method

Oil-immersed Type Transformer

Capacity range:

6300kVA-100000kVA

Operating Ambient Temperature

+40 °C--30 °C

Operating Altitude

≤1000m

Operating Max Wind Speed

≤35m/s

Earthquake acceleration

horizontal acceleration ≤0.3g

vertica I acceleration ≤0.15g

Standard

IEC 60076-1:2000, IEC 60076-2:1993, IEC 60076-3:2000, IEC 60076-5:2006, IEC 60137:2003; ANSI, IEEE, AS, etc.

Supply Ability & Additional Information

Packaging

Seaworthy Packing

Transportation

Ocean

Supply Ability

High

HS Code

85042100

Payment Type

L/C, T/T

Delivery Time

60 Days

Place of Origin

China

Port

China Sea Port

Incoterm

FOB, CFR, CIF

Packaging & Delivery

Selling Units:

Set/Sets

Package Type:

Seaworthy Packing


Part Ⅱ: Product Features

1. Low Loss

① The transposition between parallel conductors is optimized to make the cross-link flux uniform and reduce the circulating current loss caused by magnetic flux leakage.

② Slotting process is implemented on the core small stage piece to reduce the loss of structural parts of the core and prevent local overheating.



2. High Resistance to Short Circuit

① Hydraulic transposition tools are used for conductor transposition.

② The body adopts constant pressure drying and overall assembly, and the overall assembly adopts hot set.



3. Low Noise

The iron core is "soft connected" with the oil tank as a whole to reduce the transmission of noise from the body to the oil tank.


4. Low Temperature Rise

Control of transverse eddy current losses in windings.


5. Low partial discharge, extend Transformer Service life.

Analytical calculation of the electric field and improvement of the area where the electric field is concentrated.



6. Potential distribution is effectively improved by application of software to calulate the impact potential distribution and gradient potential distribution, calculate the potential distribution between the various parts of the coil, between the coil and the coil, coil and earthing.



7. High Earthquake Resistance

The casing design uses the dynamic design method, the horizontal acceleration is taken as 0.5g, the waveform is taken as resonant sinusoidal third harmonic, and the loading part is the lower end of the casing flange seat. The transformer body adopts the static design method, and the static horizontal acceleration is 0.5g.


8. Transformers Have Good Mechanical Strength

Eliminate the weak point of structural member strength and improve the mechanical strength of structural members through software simulation calculation.


Part Ⅲ: Product Main Parameter

6300~120000/110 Two-winding Oil-immersed Transformer with NVTC

Rated Capacity (kVA)

Rated Voltage and Tapping Range

Vector Group

Impedance Voltage %

No Load Current

%

No Load Losses

kW

On Load Losses

kW

HV

Tapping Range %

LV

6300

110, 121

±2×2.5%

6.3, 6.6, 10.5, 11

YNd11

10.5

0.77

9.3

36

8000

0.77

11.2

45

10000

0.72

13.2

53

12500

0.72

15.6

63

16000

0.67

18.8

77

20000

0.67

22

93

25000

0.62

26

110

31500

0.6

30.8

133

40000

0.56

36.8

156

50000

0.52

44

194

63000

0.48

52

234

75000

12~14

0.42

59

278

90000

0.38

68

320

120000

0.34

84.8

397


6300~100000/110 Three-Winding Oil-immersed Transformer with NVTC

Rated Capacity (kVA)

Rated Voltage and Tapping Range

Vector Group

No Load Current

%

Impedance Voltage %

No Load Losses

kW

On Load Losses

kW

HV

MV

LV

Step up

Step down

6300

110±2×2.5%, 121±2×2.5%

35, 38.5

6.3, 6.6, 10.5, 11

YNyn0d11

0.82

HV~MV: 17.5~18.5

HV~LV: 10.5

MV~LV: 6.5

HV~MV: 10.5

HV~LV: 17.5~18.5

MV~LV: 6.5

11.2

47

8000

0.78

13.2

56

10000

0.74

15.8

66

12500

0.7

18.4

78

16000

0.66

22.4

95

20000

0.65

26.4

112

25000

0.6

30.8

133

31500

0.6

36.8

157

40000

0.55

43.6

189

50000

0.55

52.0

225

63000

0.5

61.6

270

75000

0.5

70.2

307.7

80000

0.5

73.7

323

100000

0.5

87.1

381.8


6300~100000/110 Two-winding Oil-immersed Transformer with NVTC

Rated Capacity (kVA)

Rated Voltage and Tapping Range

Vector Group

Impedance Voltage %

No Load Current

%

No Load Losses

kW

On Load Losses

kW

HV

Tapping Range %

LV

6300

110

±8×1.25%

6.3, 6.6, 10.5, 11

YNd11

10.5

0.8

10

36

8000

0.8

12

45

10000

0.74

14.2

53

12500

0.74

16.8

63

16000

0.69

20.2

77

20000

0.69

24

93

25000

0.64

28.4

110

31500

0.64

33.8

133

40000

0.58

40.4

156

50000

0.58

47.8

194

63000

0.52

56.8

234

75000

0.63

64.7

266.7

80000

0.63

67.9

297.9

100000

0.63

80.3

330.9


6300~100000/110 Three-winding Oil-immersed Transformer with OLTC

Rated Capacity (kVA)

Rated Voltage and Tapping Range

Vector Group

Impedance Voltage %

No Load Current

%

No Load Losses

kW

On Load Losses

kW

HV

MV

LV

6300

110±8×1.25%

35, 37, 38.5

6.3, 6.6, 10.5, 11

YNyn0d11

HV~MV: 10.5

HV~LV: 17.5~18.5

MV~LV: 6.5

0.95

12

47

8000

0.95

14.4

56

10000

0.89

17.1

66

12500

0.89

20.2

78

16000

0.84

24.2

95

20000

0.84

28.6

112

25000

0.78

33.8

133

31500

0.78

40.2

157

40000

0.73

48.2

189

50000

0.73

56.9

225

63000

0.67

67.7

270

75000

0.84

77.2

307.7

80000

0.84

81

323

100000

0.84

95.7

381.8

Note

1: For transformer with OLTC, temporarily provide step-down structure product

2: Distribution of HV/MV/LV coil capacity is (100/100/100) %

3: Vector group label can be YNd11y10 according to requirements

4: Maximum current tap at - 10% tap position

5: According to customer demand, voltage value or tapping position of MV can be different from those in the above tables


6300~100000/110 Three-winding Oil-immersed Transformer with OLTC

Rated Capacity (kVA)

Rated Voltage and Tapping Range

Vector Group

Impedance Voltage %

No Load Current

%

No Load Losses

kW

On Load Losses

kW

HV

LV

6300

110±2×2.5%

121±2×2.5%

35, 37, 38.5

YNd11

10.5

0.84

10

39

8000

0.84

12

47

10000

0.78

14

55

12500

0.78

16.4

66

16000

0.72

19.6

81

20000

0.72

23.2

99

25000

0.67

27.4

116

31500

0.67

32.4

140

40000

0.61

38.6

164

50000

0.61

46.2

204

63000

0.56

54.6

245

75000

0.70

62.2

279.2

80000

0.70

65.3

293.1

100000

0.70

77.2

346.5


Part Ⅳ: Structural Diagram


Part Ⅴ: Quality Warranty


Part Ⅵ: Application


Part Ⅶ: Packaging and Transportation


Before packing the transformer, make a packing plan, and carry out packing according to the design scheme and plan when packing. The packing list corresponds to the materials in the box one to one. Pack the box in two copies, one in the packing box and the other nailed outside the packing box. Important parts and spare parts are packed in wooden boxes, and the box numbers are set in order.

The transformer is transported in bare installation, and the fuel tank is emptied before transport. It is tied to a transport vehicle by a wire rope, and the transport speed does not exceed 15km/h.

The terminal is guaranteed to have large-scale transformer lifting equipment, and the lashing is firm after loading to ensure safe and reliable transportation.


Part Ⅷ: Factory Tour


Part Ⅸ: Service Guarantee

1. To provide all technical information and drawings as per contract promptly. QRE is oblidged to invite client, if neccessory, technical design review.

2. To carry out spot technical service as per client’s schedule, offer guideness for installation and commis-sioning according to technical information and drawings.

3. For relevant auxiliary equipment procured by customers, QRE will provide related technical information to meet requirement of equipment interface.

4. To execute stipulations in MOU or agreemaent signed by seller and buyer strictly.

5. To train staff from client for equipment installation, commissioning, application, maintenance as stipulated in the contract.

6. To reinforce pre-sales, mid-sales, after-sales service, to carry out "24-hour service", "service in advance", "overall process service", "lifelong service" in our manufacturing, installation, commissioining and main-tance.

7. To meet spare parts’ requirement by customers at any time.


Part Ⅹ: Contact Us

Looking for ideal 110kV 3-phase 2-winding Power Transformer Manufacturer & supplier ? We have a wide selection at goods prices to help you get creative. All the 110kV 3-phase 2-winding Power Transformer are quality guaranteed. If you have any question, please feel free to contact us.